Flat Roofs

With rigid insulating fall layers of lightweight concrete have a light, durable construction with a firm, straight slope, which reliably ensures water drainage, thermal insulation, and longevity and is cost-effective.

Flat Roofs
Flat Roofs
Flat Roofs
Flat Roofs
Flat Roofs
Flat Roofs
Flat Roofs

Fall layers of flat roofs

Made of Lightweight Concrete - Foam Concrete (FC), and Polystyrene Concrete (PC), thanks to their thermal insulation properties, strength, low costs, simple implementation, and low weight, are a proven effective technological solution for the construction of stable and durable thermal insulation structures of flat roof jackets with classic or inverted order of layers.

They are a reliable solid substrate for waterproofing, insulation, or paving. They reliably ensure rainwater drainage and prevent its accumulation (ponding) and infiltration into the building, increasing the durability and service life of the roof waterproofing and insulating layers.

They simplify, speed up and cheapen the construction and reconstruction of flat roof jackets.

Roof Screeds Laid to Falls

Fall layers of lightweight concrete (LC) are lightweight insulating roof screeds laid to falls. Their thickness gradually decreases towards the water outlet. They are installed on the roof slab to create the required roof slope for reliable rainwater drainage from any point of the roof towards the roof drains, downpipes, guttering systems, etc.

LC alone or in combination with board thermal insulation successfully replaces cinder concrete, perlite concrete, various backfills and plastic slopes.

After hardening, LC fall layers form volume and strength-stable cohesive structures with high dynamic stiffness at a low dead load, zero lateral loads on adjacent structures, and good thermal insulation properties.

Substrate for Waterproofing

Fall layers of foam concrete or polystyrene concrete are significantly more durable and more than 4 times stronger than plastic fall layers. They have a cohesive, solid and even surface suitable for melting waterproofing.

The main advantages of LC Fall Layers

  • Are stable and incompressible with a solid, smooth surface
  • Have a solid and cohesive thermal insulation structure
  • Low loading of the supporting structure
  • High resistance to fire and flooding
  • Quick implementation thanks to shape adaptability
  • Easy height accessibility by pump

Lightweight Concretes for fall layers

PBG*-Foam Concrete for fall layers

Foam 
Concrete 
PBG 
50 
1 10 
60 
mn 1 30 
70 
min 1 50 
min 1 80 
80 
Dry 
Density 
kg/m3 
500 
600 
700 
800 
Compressive 
Strength f, 
N/mm2 
Coef. Of Thermal 
Conductivity 
W/mK 
max 0.130 
max 0.170 
max 0.210 
max 0.250 
Min Amb. 
Temperat. 
5 
5 
5 
5

* PBG is a trademark of Foam Concrete produced by SIRCONTEC technology

PsB*-Polystyrene Concrete for fall layers

Polystyrene 
Concrete 
PsB 
40 
50 
60 
min 1 10 
70 
min 1 90 
80 
Dry 
Density 
kg/m3 
400 
500 
600 
700 
800 
Compressive 
Strength fc 
N/mm2 
min 0.50 
min 0.80 
min 
1.50 
Coef. Of Thermal 
Conductivity 
W/mK 
max 0.100 
max 0.120 
max 0.140 
max 0.180 
max 0.230 
Min Amb. 
Temperat. 
15 
8 
5 
5 
5

* PsB is a trademark of Polystyrene Concrete produced by SIRCONTEC technology

Note: FC modifications PBG 35, 40, 45 a 50 and PC modifications PsB 40, 50 a 60 are certified building materials - see Technical Assessment TSÚS SK TP-14/0118

The pumpability of LC SIRCONTEC can be more than 70m in height and 300m in distance.

The selection of a suitable LC modification is mainly based on the ambient temperature, the ability to form a flat roof gradient, and the onset of walkability.

The most frequently used LC modifications:

  • Foam concrete PBG 50 - 80, suitable for fall layers with a slope of up to 2%; for steeper slopes, special procedures are necessary
  • Polystyrene concrete PsB 50, appropriate for fall layers with a slope of up to 3% and PsB 60 - 80,  intended for slopes exceeding 10%, with an app thickness of up to 1000mm.

Single-skin flat roof construction

Roof with a classic layer order with an insulating fall layer made of LC

PBG / PsB 
Waterproofing layer 
- asphalt strips are fused 
to the surface of PBG or PsB 
Fall layer Of LC 
- foam concrete PBG or 
polystyrene concrete PsB 
Load-bearing layer 
- reinforced concrete roof slab, 
or trapezoidal plate, ceramic slab, 
original roof covering, etc.

LC creates a cohesive structure of the fall layer with a solid and smooth surface suitable for fusing waterproofing.

The LC modification and the minimum thickness of the falling layer are given by static, respectively, thermal engineering calculations.

Roof with a fall layer made of LC and board thermal insulation

Even though lightweight concrete used in roofs has significant thermal insulation properties, we recommend using board polystyrene with a density of at least 30kg/m³ to achieve the required thermal resistance.

With the "classic" order of roof jacket layers, it is most suitable to place the board thermal insulation layer under the layer of lightweight concrete. In this case, the board polystyrene is in a temperature-stable environment without temperature fluctuations and is protected from ozone and UV radiation.

Waterproofing layer 
- asphalt strips are fused 
to the surface of PBG or PsB 
PBG / PsB 
layer Of LC 
unununun• •unununu 
- foam concrete PBG or 
polystyrene concrete PsB 
combined with board EPS / XPS 
Load-bearing layer 
- reinforced concrete roof slab, 
or trapezoidal plate, ceramic slab, 
original roof covering, etc.

The thickness of the LC layer above the board polystyrene should not fall below 80mm.

The lightened, bound, and incompressible fall structure has high thermal resistance and load-bearing capacity, is resistant to fire and flooding, and is suitable for all flat roofs.

Waterproofing layer - SIRCONTEC recommends anchoring the roof coating by melting it into a penetrated foam concrete or polystyrene concrete subbase while simultaneously creating a micro-ventilation slot with a connection to the atmosphere. After melting the upper bitumen strip, it is necessary to load it down.

We do not recommend mechanical anchoring of the coating covering to LC with a dry density of up to 600kg/m³. Suppose it is necessary to use the mechanical method of anchoring. In that case, it is advisable to apply a layer of concrete screed in the required thickness to the layer of FC and PC or to fasten the mechanical anchor down to the roof slab.

Realisation of flat roof fall layers

To realise FC fall layers, we provide implementation companies with complete production and processing know-how, including the delivery of production technology equipment developed by us.

It is necessary to follow the general conditions for producing and processing lightweight concrete, as well as the production procedures and technical sheets of SIRCONTEC.

Preparation of the roof area for the implementation of FC fall layers

The area where the fall layer will be installed should be pre-bounded with masonry and formwork or guide strips from PsB-polystyrene concrete.

To facilitate the realisation of fall layers, we recommend creating separate fall fields with the help of formwork. The upper edge of the formwork is placed at the height level of the fall, to which the LC will be applied.

Calculation of the fall layer volume

SIRCONTEC provides its customers with a calculator for calculating the volume of the roof fallout layer - a calculation system for determining the necessary amount of fallout mass of all fallout fields  (V1 - V8) for individual roof drainage fields.

% - slope away from the corners 
Uppérsurface of VI & V2 is an inclined plan 
Valley between falling fields VI & V8 
Starting slope level in % 
Roof Drain

Axonometry of one roof falling field - "pyramid" V1

When determining the minimum slope percentage of the roof falls, it is necessary to consider the roof waterproofing covering material supplier's application regulations and that the 1-percent slope is eliminated by shifting the adjacent fusible asphalt strips necessary to connect them by fusion.

​Reconstructions of roofs

The method described here for making the fall-thermal insulation layer using LC is particularly advantageous for roof reconstructions, as there is no need to dismantle and remove the existing, original layers of the reconstructed roof.

Renovation of pitched roofs

A very economical way of renovating sloping roofs (eliminating their leaks)  with a slope gradient of up to 15° with a covering made of trapezoidal sheet metal or corrugated eternity is to use the existing covering as a lost formwork for the polystyrene concrete PsB 60 layer.

The PC will even out the corrugated subbase, creating a flat surface that will allow the installation of standard waterproofing coating covering while preserving the roof's original slope.

When using PC PsB 60, it is recommended to use a full-area reinforcement of the PsB 60 layer with a KARI mesh mechanically anchored to the subbase.

The structural engineer and the construction physicist designed the thickness of PsB 60 and the type of KARI mesh.

Whether reconstructed or newly built, the entire roof structure should always be designed by structural engineers authorised in building physics and statics.

Examples of flat roof constructions

Stable fall layers made of LC SIRCONTEC are suitable for single-skin flat roof structures with a classic or reversed order of layers, as well as double-skin roof structures:

Walkable roof - classic layer order

PBG / PsB 
•ununun• nunununu 
Walkable layer 
- e.g., paving made of washed 
concrete laid on pads 
Separation and filter layer 
— optional layer (geotextile) 
Waterproofing layer 
Fall layer of LC 
- foam concrete PBG or polystyrene 
concrete PsB combined with board EPS / XPS 
Load-bearing layer 
- reinforced concrete roof slab, or trapezoidal 
plate, ceramic slab, original roof covering, etc.

Vegetation roof - classic layer order

PBG / PsB 
Vegetation layer 
- the soil thickness depends on the height of 
the green growth, or the type of vegetation 
(extensive / intensive green roof type) 
Separation and filter layer 
— geotextile 
Drainage layer 
- shaped foil 25 mm thick, or a layer of 
aggregates fraction 4/8 mm, 50 mm thick 
Separation and filter layer 
— geotextile 
Waterproofing layer 
Fall layer of LC 
- foam concrete PBG or polystyrene 
concrete PsB combined with board EPS / XPS 
Load-bearing layer 
- reinforced concrete roof slab, or trapezoidal 
plate, ceramic slab, original roof covering, etc.

Non-walkable roof - classic layer order

Waterproofing layer 
Thermal insulation layer 
- hardened mineral fibre boards for roofs 
Vapor barrier 
- asphalt strips with an aluminium insert 
PBG / PsB 
are fused to the surface of the LC 
unununun• nunununu 
Fall layer of LC 
- foam concrete PBG or polystyrene 
concrete PsB combined with board EPS / XPS 
Load-bearing layer 
- reinforced concrete roof slab, or trapezoidal 
plate, ceramic slab, original roof covering, etc.

Vapour barrier - a barrier against the vertical movement of water vapour, most often an asphalt strip with an aluminium insert, anchoring by melting to the LC layer while simultaneously creating a micro-ventilation layer; the air gap of the micro-ventilation layer must be connected to the free atmosphere in the parapet and on the transitions.

Non-walkable roof - inversed layer order

Walkable roof - inversed layer order

Walkable and loading layer 
- e.g., paving made of washed 
concrete laid on pads 
Separation and filter layer 
— geotextile 
nnnånniß 
Thermal insulation layer 
- XPS extruded polystyrene boards 
PBG / PsB 
Waterproofing layer 
Fall layer of LC 
- foam concrete PBG or 
polystyrene concrete PsB 
Load-bearing layer 
- reinforced concrete roof slab, or trapezoidal 
plate, ceramic slab, original roof covering, etc.

Vegetation roof - inversed layer order

PBG PsB 
vegetation layer 
- the soil thickness depends on the height of 
the green growth, or the type of vegetation 
(extensive / intensive green roof type) 
Separation and filter layer 
— geotextile 
Drainage layer 
- shaped foil 25 mm thick, or a layer of 
aggregates fraction 4/8 mm, 50 mm thick 
Separation and filter layer 
— geotextile 
Thermal insulation layer 
- XPS extruded polystyrene boards 
Waterproofing layer 
Fall layer of LC 
- foam concrete PBG or polystyrene 
concrete PsB combined with board EPS / XPS 
Load-bearing layer 
- reinforced concrete roof slab, or trapezoidal 
plate, ceramic slab, original roof covering, etc.

Double-skinned roof with an upper skin made of LC

Beam 
PBG / PsB 
mammnmun 
Heraklith board 
Waterproofing layer 
Fall layer of LC 
- foam concrete PBG or polystyrene 
concrete PsB with a slope of more than 30 
Supporting roof structure 
- parts made of lightweight concrete, e.g. PBG 
e—- Ventilated air layer 
Thermal insulation layer 
- boards made of mineral fibres 
with a higher density 
Thermal insulation layer 
- mineral fibre boards 
Load-bearing layer 
- reinforced concrete roof slab, or trapezoidal 
plate, ceramic slab, original roof covering, etc.

The main benefits of SIRCONTEC roof structures

  • Have a durable, bound and solid insulating construction of the roof jacket
  • Reduce the dead load and the thickness of the roof jacket
  • Fall layers have solid, cohesive and smooth surfaces suitable for fusing waterproofing
  • Are resistant to fire and flooding
  • Simplify,  speed up and cheapen the construction and reconstruction of flat roofs

More information on the topic

  • Documents, technical sheets and presentations are attached or in the Documents > Roofs section
  • Images, photos, or videos are below on the page or in the Gallery > Roofs section
Sme tu pre vás

Potrebujete poradiť?

Kontaktujte nás